XN-9100

Concentrated power for your growing demands

Sample and validation workflows were never as easy to implement as with the XN-Series’ automation solutions. Modularity and scalability are not just buzzwords, but a reality our customers experience every day. Based on an in-depth analysis of your individual situation, we develop a tailored solution around your prime needs. By initially selecting individual analytical modules, clinical applications and sample routing optimisation, you get the most efficient sample processing system on the smallest footprint. Intelligent sample routing and real-time reflex decisions guarantee the best possible TAT for all samples.

The result: when the sample is presented to you in the validation screen, you can be sure that the information needed to judge the results was already generated by the system, even in several cascading steps.  

Its fundamental components include at least two XN analysis modules, plus at least one slide maker /stainer module, the SP-50. As customer situations and needs vary significantly, we offer the XN-9100 in different core configurations, all of which are modular and scalable to best suit individual needs.

*only in certain countries

Technical Specifications
Measurement principles WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Throughput
From 2 modules of XN-10/20 in
combination with SP-50 (H mode):


from 200 samples/h in whole blood (WB) mode,
up to 40 samples/h in body fluid (BF) mode per module,
up to 30 slides/h in standard mode per module,
up to 75 slides/h with the optional high-throughput licence per module
Aspiration volume
XN module:
SP-50 module:

88 μL in whole blood (WB) mode and body fluid (BF) mode
70 μL for smear preparation in auto mode,
38 μL for smear preparation in manual mode
Analysis parameters
Whole Blood

With RET (optional)
With PLT-F (optional)
With WPC (optional)
XN Stem Cells licence:
Body Fluids with XN-BF
(optional)

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV,
P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O
PLT-F, IPF, IPF#
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#
HPC%, HPC#
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
Sampler unit capacity 25 racks (250 samples) – Start Yard (ST-40) capacity
Integrated optional module DI-60 for digital image analysis
Tube sorter TS-10
Tosoh HLC-723 G11* – automated glycohaemoglobin analyser
Interrliner* – automated ESR reader
Staining protocols (SP-50) May Grünwald – Giemsa, Wright – Giemsa, Wright
Data storage capacities
(XN module)

Results: 100,000 samples
Patient information: 10,000 records
QC files: 99 files (300 plots per file)
Reagent replacement history: 5,000 records
X-bar control (L-J control): 300 plots x 94 files
X-barM control: 300 plots x 5 files

 

Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Middle East FZ-LLC

Dubai Healthcare City

City Pharmacy Building C/P 72, Office 304

P.O. Box 505119 Dubai, U.A.E.

+971 4 4370515

+971 4 4370516

Documents

Product documents

Safety data sheets

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

Copyright © Sysmex Europe SE. All rights reserved.